Description
Scope
This specification covers Irrigation Cable with soft annealed stranded copper conductors insulated with polyethylene (PE). The insulated conductors are cabled together with a PVC inner jacket, and an aluminum shield bonded to a PE outer jacket to provide superior mechanical strength and moisture resistance. The cable conforms to UL Standard 1263.UL File No. E325277.
Application
Irrigation Cable is designed for electric motor–driven irrigation systems, including agricultural irrigation equipment, sprinkler systems, and valve control wiring. It is rated for 75°C operation and permitted for 600-volt applications. Suitable for outdoor, underground, and wet locations.
Construction
- Conductors: Soft annealed stranded copper, bare or coated.Available sizes: 18 AWG–4/0 AWG
- Insulation: Polyethylene (PE) with thickness per UL1263.
- Inner jacket: Flame-retardant PVC. Minimum average wall thickness 0.76mm.
- Shield: Corrugated aluminum specially coated and applied in order to bond to the outer jacket with a total minimum thickness of 0.2mm.
- Outer jacket: Sunlight resistant PE. Minimum average wall thickness 1.27mm.
- Information on the jacket: AWG or kcmil size,conductor type letters,rated voltage, the name of the manufacturer, UL file number, characteristic, manufacture date, FEET.